Recently, the Ministry of Housing and Urban Rural Development successfully reviewed and passed two recommended national standards for wires and cables for construction in Jinan, which for the first time stipulated that the service life of wires and cables should not be less than 70 years. The new cable standard clearly requires that civil buildings with a height of more than 100 meters must use low smoke halogen-free A-grade flame retardant wires and cables. In addition, it is also mandatory to use environment-friendly cables in major construction.
Since 1992, a large number of commercial houses built in China began to change the wiring mode from open wire to concealed wire. At that time, the service life of domestic wires was only 25 years due to technology, process, materials and other factors. 70 years of construction life, 70 years of housing property rights and 25 years of wire and cable life are seriously out of sync, and hidden dangers also arise.
Fu Ping, deputy director of the Jinan Public Security Fire Brigade, said that if the wires and cables were out of service, they would be short circuited or tripped, and serious lighting and burning would cause fires. At present, some professional organizations both in China and abroad are actively formulating new cable standards to encourage and require cable enterprises to produce green and environment-friendly cables. For example, relevant laws and regulations in China explicitly require that PVC wires and cables are prohibited in important buildings, and halogen-free low smoke cross-linked polyolefin insulated wires and cables must be used to avoid heavy smoke, chlorine and casualties in case of fire. Beijing Plastic Yihang Cable: 010-83298180 Room 406, Jingchen Ruida Building, Wulidian North District, Fengtai District, Beijing According to the new cable standard, smoke-free, low halogen and flame retardant cables shall be used at least for high-rise buildings with a height of more than 100 meters and civil buildings with a height of less than 100 meters, such as hospitals, public * * * offices, underground shopping malls, libraries, stations, supermarkets, terminals, office buildings, etc. of a certain scale. Today, the two standards for wires and cables used in construction have successfully passed the review of the Ministry of Housing and Urban Rural Development. For the first time, it is stipulated that the service life of wires and cables should not be less than 70 years, which is synchronized with the service life of 70 year property houses.
After the new cable standard is released, more decoration owners and real estate development enterprises will choose wires and cables with fire and electricity saving and durable performance. 70 year long life cable This is a good thing for the country and the people.