Fireproof cable

Date of issue: 2017-12-04 Author: sxhengnuo.cn Click:

 Fireproof cable.jpg

Fireproof cable characteristic:

Conductor: multi strand copper stranded wire.

Insulation: mechanically wrapped with high-temperature resistant synthetic mica tape.

Filling layer: use alkali free glass fiber for dense filling.

Sheath: longitudinally wrapped with copper strip, welded into copper pipe, and then formed by continuous rolling corrugation.

Use: This product is original in China, and there is no prototype in the world. Compared with the BTTZ series, the product maintains a high degree of fire resistance, and can achieve continuous large length. It can also be made into multi-core group cables within 95mm2, overcoming the shortcomings of too many joints and too difficult construction.   

Characteristics of fireproof cable:

1. The fire resistance performance is excellent, and the fire resistance rating exceeds the 1.5h combustion requirement of Class C 950 ℃~1000 ℃ specified in the British standard BS6387-1994. At the same time, it can withstand water spray and mechanical impact during combustion.  

2. The continuous production length is long, whether it is single core or multi-core cable, its length can meet the demand of power supply length, and the length can reach more than 2000 meters. No joints are required in the middle.  

3. Large cross section, single core cable cross section can reach 630mm2, multi-core cable can reach 240 mm2.  

4. It is flexible, and the cable can be coiled on the cable reel, with the bending radius > 20D.  

5. It is non-toxic and smokeless when burning, and does not produce any harmful gas after burning. It is an environmental protection and green product.  

6. Large overload capacity. The cable not only has large current carrying capacity, but also has large overload capacity. The allowable working temperature of the cable under overload is 250 ℃.  

7. Good corrosion resistance. Inorganic mineral insulated fireproof cable adopts copper sheath, which does not need to be threaded. The copper sheath has good corrosion resistance.  

8. There is no electromagnetic interference. When the cable is laid together with signal, control and other wires and cables, the inorganic mineral insulated fireproof cable will not interfere with the signal transmitted by the signal line and control cable under the shielding of the copper sheath.  

9. Good safety. In addition to the normal power supply in the flame, the cable can start the fire-fighting equipment to reduce fire losses, and it is also particularly reliable for personal safety. Its copper sheath is the best grounding wire, greatly improving the sensitivity and reliability of grounding protection.  

10. The transportation and installation of inorganic mineral insulated fireproof cables are similar to ordinary cables, which are relatively simple.  

11. Good economy, inorganic mineral insulated fireproof cable has advanced manufacturing process and simple installation, and its comprehensive cost is significantly lower than that of BTTZ mineral insulated cable under the same conditions.

Introduction to fireproof cable:

The conductors of YTTW series metal sheathed inorganic mineral insulated fireproof cables are stranded copper wires, the insulation is mechanically wrapped with high-temperature resistant synthetic mica tape, the insulation layer is densely filled with alkali free glass fiber, the sheath is longitudinally wrapped with copper tape, welded into copper tubes, and then formed by continuous rolling ripple. Where the metal sheath can not be exposed according to specific requirements, a layer of polyolefin (low smoke zero halogen) sheath can be added outside.

Executive standard of fireproof cable:

1. JG/T 313-2011 Metal sheathed inorganic mineral insulated cable and terminal with rated voltage of 750V and below.

2. BS 6387:1994 Performance requirements for cables to maintain circuit integrity under flame conditions.

3. Follow the corresponding enterprise standards.

Applicable scope of fireproof cable:

It mainly includes power supply for fire fighting equipment, power supply for fire elevator, places with high ambient temperature, power supply for equipment and lighting system in buildings or densely populated buildings, places requiring special sanitation, important inflammable and explosive places, etc.

Use characteristics of fireproof cable:

1. Voltage class: 0.6/1kV, working voltage light load 500V, heavy load 750V.

2. Working environment: the long-term working temperature is 70 ℃ for the sheath; The long-term working temperature of mineral insulated cables in the places where no one touches is 105 ℃.

3. Bending radius: the allowable minimum bending radius is ≥ 20D.

Requirements for use of fireproof cable:

1. Installation conditions: It is suitable for open laying by ladder, or cable tray laying or embedding. A single core is not suitable for passing through metal pipes.

2. Installation process: there are special connectors, refer to the manufacturer's Installation Instruction Manual for details.

3. Precautions: cable support and fixation

A、 Allowable span of horizontal hanger 1) Cable outer diameter ≤ 20mm, allowable span 400mm

2) The outer diameter of the cable is>20 mm, and the allowable span is 800 mm.

B、 Allowable span of vertical support 1) Cable outer diameter ≤ 20 mm, allowable span 1500 mm

2) The outer diameter of the cable is>20 mm, and the allowable span is 1000 mm.

C、 For laying in cable tray, the allowable span of fixed cable can refer to items a and b.

D、 The bending radius of the cable is 20D (outer diameter of the cable).

E、 The fixation of single core cable shall not be made of high magnetic conductivity materials with magnetic closure, such as binding with iron wire, but can be fixed with non-magnetic materials or magnetic unclosed magnetic components.

F、 The mechanical strength of the fixed components of the single core cable shall be checked and calculated according to the short circuit electrodynamic conditions. The fixed spacing shall avoid AC vibration and noise.

G、 Hacksaw and tools that are easy to produce metal chips or burrs are strictly prohibited for splitting cable copper sheath.

H、 It is strictly prohibited to embed metal and burr into inorganic insulating materials at the stripped joints of cables.


Website: //sxhengnuo.cn/news/360.html

Related labels: Specification of fireproof cable , Fireproof cable model , Fire cable price

Recent browsing:

contact us

Shandong Peninsula Cable Co., Ltd

Tel.: 0535-8621134

Q        Q:1653178622

Email: [email protected]

Address: Tonghai Road, High tech Development Zone, Longkou, Shandong

 New energy cable 1522035370290487.png